DNO applications and SLDs, approved without the back-and-forth.

14

DNO regions

6

Network operators

G98–G100

Applications & schemes

ENA

Type-test compliant

What we do

The documentation that clears your connection.

We specialise in the design and paperwork behind a DNO connection — the SLD, the settings and the pack — so your application is accurate and complete from the outset.

 

DNO applications (G98 & G99)

We prepare and submit G98 notifications and G99 applications on the correct form, to the correct DNO, so your connection moves without avoidable delays.

 

Application types

G98

G99

Formerly G59

All 14 DNO regions

SLD contents

Point of connection

Isolation

Protection

Metering

Single line diagrams (SLDs)

DNO-format single line diagrams that show the point of connection, protection and isolation clearly — the single document that most often makes or breaks a G99 application.

 

Protection settings schedules

Relay and protection parameters drawn from the inverter’s ENA type-test certificate and matched to your SLD and application — so nothing conflicts under DNO review.

 

Protection

ENA type-test

Relay settings

Loss-of-mains

V & f limits

Limitation scheme

G100/2

CLS

Export limit

Connect Direct device

G100 export & import limitation

Where the network won’t accept full export, a G100-compliant Customer Limitation Scheme caps export at the agreed capacity — letting a larger PV or battery system connect. We design the scheme and prepare the CLS application.

 

Fault level & load flow analysis

For larger and HV/EHV connections, fault level and load flow studies that support the application and satisfy the DNO’s technical review.

 

Network studies

Fault level

Load flow

HV / EHV

Cable coordination

In the pack

SLD

Protection

Datasheets

ENA certs

Summary

Full application documentation pack

Every document the DNO expects, consistent with one another. The mismatched figures that trigger information requests never leave our desk.

 

Solar, BESS & EV connections

Solar PV, battery storage and EV charging connections — from a single commercial site to a solar farm — prepared for DNO approval on one standard.

 

Project types

Solar

BESS

EV charging

Solar farms

Inside the pack

Everything the DNO asks for in one place.

A Vishtik application pack arrives complete and internally consistent — drawn to the format your DNO requires.

 
 

Single line diagram (DNO format)

Protection settings schedule

Completed G98 / G99 application form

System summary & capacity data

Inverter datasheets & ENA type-test certs

Fault level analysis

Letter of Authority guidance

Planning status guidance

G100 Customer Limitation Scheme (CLS) application

G100 commissioning test forms (Appendix B)

Responses to DNO information requests

How it works

From project details to connection offer.

One clear path — and we manage the DNO conversation the whole way through.

1

Submit

Intake & scope

Site, inverter, capacity and connection details.

2

Analyze

SLD & documents

DNO-format SLD, protection settings and pack prepared.

3

Design

QC review

Every figure checked to agree across documents.

4

Model

DNO submission

Correct form, correct DNO, submitted for you.

5

Deliver

Manage queries

We answer DNO information requests on your behalf.

5

Deliver

Connection offer

Approval and connection offer handed back to you.

DNO coverage

Every network operator every region.

We prepare applications to the right form and format for all six UK network operators, across all 14 distribution licence areas.

UK Power Networks

National Grid Electricity Distribution

Northern Powergrid

SP Energy Networksv

Electricity North West

Scottish & Southern (SSEN)

Why Vishtik

Accurate and complete, in from the outset.

Most DNO delays are avoidable. Here’s how we keep your application moving.

 
 

Right form, right DNO

Each network operator has its own form. We use the correct one, filled correctly, every time.

Documents that agree

SLD, settings and form checked against each other — the mismatches that cause information requests are caught first.

ENA-compliant settings

Protection settings drawn from the inverter's type-test certificate — not guessed, not generic.

Queries handled for you

When the DNO comes back with questions, we answer them — so you're not chasing technical detail.

Capacity to scale

150+ engineers behind every application — from a single site to a portfolio of connections.

Confidential by default

We never reuse your designs or list you as a reference without consent. Your projects stay yours.

Talk to a Grid Connection Expert

Start a single project or hand us a backlog. Either way, you get a dedicated team, a clear delivery time, and a portal that shows exactly where every set stands.

Recognized certification & membership

ISO 9001:2015 certified quality management badge
Solar Energy Industries Association logo

Engineering you don’t have to chase

Solar design, PE stamping, permitting and interconnection, run on one path, with a name on every project and a portal that shows exactly where each file stands.

Vishtik logo with white wordmark

A US-facing solar engineering and permitting firm. We move installer and EPC projects through design, compliance and delivery across all 50 states, on one standard.

Stay ahead

Solar industry updates, engineering insights & exclusive Vishtik offers.

One email a month. Unsubscribe anytime.

United States · Office

Wyoming

1021 E Lincolnway, Suite #7803, Cheyenne, Wyoming 82001, US

India · Engineering & Design Center

Delhi

Near IGIA, 
Delhi, India

India · Engineering & Design Center

Dehradun

IT Park, 
Dehradun, India

© 2026 Vishtik. All rights reserved.